MODELS VSS, VSSAP, & VSESA SINGLE SOLENOID


SINGLE SOLENOID
(GENERAL PURPOSE)

MODEL
PRESSURE PILOT

VSS

A maintained electrical contact is required to shift the valve. Breaking the electrical contact will return the valve to its original position.

MODEL
PRESSURE PILOT

VSSAP

A momentary (NOT continuous) electrical contact is required to shift the valve. It will remain in that position until a separate momentary pilot pressure is applied to the spool cap opposite the solenoid, returning the valve to its original position. Pilot pressure must be at least 25% of the operating pressure.

MODEL
BLEED PILOT

VSESA

A momentary (NOT continuous) electrical contact is required to shift the valve.

A separate Bleeder Valve, such as the Allenair BV100 or BV-1/8, must be installed in the line to the spool cap opposite the solenoid.

Depressing this Bleeder Valve momentarily will return the valve to its original position.


NOTES:

  1. MODELS VSS & VSSAP: ENERGIZING SOLENOID PRESSURIZES CYLINDER PORT DIRECTLY UNDER SOLENOID.
  2. MODEL VSESA: ENERGIZING SOLENOID PRESSURIZES CYLINDER PORT OPPOSITE SOLENOID.
  3. EXHAUST PORT IS LOCATED 180° FROM SPEED CONTROLS.

OPTIONS (SOLENOID VALVES)

SPECIFY HTP FOR HIGH TEMPERATURE SEALS
These seals are a fluorocarbon compound (viton) and have an operating temperature range of +10 degrees F to +350 degrees F. They will function at temperatures up to +400 degrees F with reduced life.

SPECIFY IL FOR INDICATOR LIGHT (AAS OPERATOR ONLY)
Light indicates when solenoid is energized.

SPECIFY OR FOR MANUAL OVER-RIDE LEVER
These are non-locking and are particularly useful for set-up or electrical failure.

SPECIFY PE FOR PIPED EXHAUST ADAPTERS
Enables the solenoid exhaust to be piped from the actuator.


SOLENOID OPERATORS

AAC CONDUIT HOUSING UL & CSA Listed.
AAD DIN-type HOUSING A male connector configuration of DIN 43650/ISO 4400. Click Here for female connectors.
AAG GROMMET HOUSING UL & CSA Listed.
AAS SPLICE BOX HOUSING  STANDARD, UL & CSA Listed.
AAX EXPLOSION PROOF UL Listed covering Class I Groups C & D (NEMA 7) and Class II Groups E, F & G (NEMA 9).
AAY SPADE TERMINALS UL & CSA Listed.
JIC NEMA 4/IP-56  Water Tight per NEMA 4/IP-56
AAN6 NEMA 6 Water Tight per NEMA 6

Click Here To View/Download PDF For 4 Way 1/4 & 1/2 NPT

Pneumatic Cylinders, Digital feedback air Cylinders, Air Cylinders, Small Bore Cylinders, Valve In Heads Cylinders, Cyl Check Cylinders, Air Clamp Cylinders, Small Bore SS Cylinders, Position Feedback Cylinders, Valves, 4 Way ¼, 3/8, & ½ NPT Valves, 2 Way, 3 Way Solenoid 1/8 & ¼ NPT Valves, 4 Way Direct Acting 1/8 NPT Valves, Time A Valve, Air Switch Valve, 1/8 NPT Poppet Valve